Cyronics - Industrial Division

 
Chauvin Aurnox

CA1510 digital current logger clamp

Chauvin Arnoux Make C.A 1510 Logger

In addition to its portable function, the simple, user-friendly C.A 1510 is capable of recording the parameters measured and monitoring air quality criteria based either on the level of CO2 or on a combination of the three physical quantities measured.   
•    CO2: 0 to 5,000 ppm
•    Accuracy: ± (50 ppm + 3% of the value measured)
•    Temperature: -10 °C to +60 °C
•    Accuracy: ± 0.5 °C
•    Humidity: 5 to 95 %RH
•    Accuracy: ± 2%RH
•    Recording: 1 million values stored on the product in the form of several measurement campaigns
•    USB interface (product recognized as a USB key) or Bluetooth for wireless use
•    Software supplied as standard and 1510 application available with Android
•    Locking of the instrument possible during recording (display & keyboard)
•    Numerous mounting possibilities (magnetized product, wall support, wall support with padlock insert, desktop stand or suspended).

CL601 digital current logger clamp

Chauvin Arnoux Make CL601 Logger

The Simple Logger II family of data loggers is a product line benefiting from advanced design and an excellent quality/price ratio when their specifications and functions are taken into account. Self-contained and equipped with protected connections, the CL601 clamp is ideal for supervision of machine loads, HVAC diagnostics, load representation, electrical troubleshooting, etc.

Specifications:
•    Range: 0 to 600 AAC RMS
•    Resolution: 0.1 A
•    Sampling rate: 64 samples/period
•    Storage interval: programmable from 125 ms to 1 day
•    Recording modes: Start/End, FIFO, XRM extended mode, on alarm
•    Recording duration: from 15 minutes to 8 weeks, programmable with DATAVIEW
•    Storage capacity: 240,000 measurements (512 kB)
•    Communication: optically-isolated USB 2.0
•    Power supply/battery life: 2 x AA 1.5V batteries / from 100 hrs to more than 45 days

L562 digital current logger clamp

Chauvin Arnoux Make L562 logger

The Simple Logger II L562 is a logger which records voltage and current simultaneously. It can be used to observe a trend recording of the apparent power on the installation.

Advantages
•    Single-phase voltage and current logger
•    Apparent power
•    Diagnostics on residential, commercial and industrial networks
•    Own power supply

Specifications:
•    One voltage input (banana plugs) from 0 V to 600 VAC
•    One current input (BNC)
•    240,000 measurements
•    Recording for up to 8 weeks
•    USB port
•    IEC 61010 300V CAT IV and 600 CAT III

PEL102 digital current logger clamp

Chauvin Arnoux Make PEL102 POWER-ENERGY LOGGER

Ergonomic, magnetized and suitable for all types of cabinets, PEL102 loggers provide all the power and energy measurements simultaneously.

Advantages
•    Single-phase, split-phase and three-phase installations with or without a neutral, as well as other complex configurations.
•    Implementation without cutting off the mains power supply
•    Bluetooth, Ethernet and USB communication
•    Automatic recognition of the sensors connected
•    Recording on SD and SD-HC cards
•    Real-time communication with a PC and analysis using PEL Transfer

Other specifications:
•    Voltage up to 1,000 V
•    Current up to 10,000 A
•    Voltage ratio / current ratio up to 650,000 V / up to 25,000 A
•     Power from 10 W/var/VA to 10 GW/Gvar/GVA
•    Energy up to 4EWh / 4 EVAh / 4 Evarh
•    Phase: cos φ, tan Φ, PF
•    Harmonics up to 50th order
•    2 GB SD memory card (SD-HC card up to 32 GB)

PEL103 digital current logger clamp

Chauvin Arnoux Make PEL103 POWER-ENERGY LOGGER

Ergonomic, magnetized and suitable for all types of cabinets, PEL103 loggers provide all the power and energy measurements simultaneously.
Single-phase, split-phase and three-phase installations with or without a neutral, as well as other complex configurations.
•    Implementation without cutting off the mains power supply
•    BlueTooth, Ethernet and USB communication
•    Automatic recognition of the sensors connected
•    Recording on SD and SD-HC cards
•    Real-time communication with a PC and analysis using PEL Transfer software

Other specifications:
•    Voltage up to 1,000 V
•    Current up to 10,000 A
•    Voltage ratio / current ratio up to 650,000 V / up to 25,000 A
•    Power from 10 W/var/VA to 10 GW/Gvar/GVA
•    Energy up to 4EWh / 4 EVAh / 4 Evarh
•    Phase: cos φ, tan Φ, PF
•    Harmonics up to 50th order
•    2 GB SD memory card (SD-HC card up to 32 GB)

L404 digital current logger clamp

Chauvin Arnoux Make L404 logger

The Simple Logger II L404 4-channel event logger is perfect for determining operating times and downtime, as well as for scheduling and counting events. The L404 event logger records up to 50,000 events. It operates with dry contact closure or 0-3 and 0-5 VDC logic levels. The recorded data are stored in non-volatile memory. They can be transferred via an optical USB link for processing. The DataView software (available as an option) can be used for quick, simple data analysis.

Advantages
•    Process synchronization research
•    Pulse counting
•    Event scheduling

Specifications:
•    up to 50,000 events
•    logic levels: 0-3 and 0-5 VDC
•    4 channels
•    IEC 61010 50V CAT III

L111 digital current logger clamp

Chauvin Arnoux Make L111 logger

The L111 logger is ideal for detecting fault currents and intermittent problems, monitoring the neutral current, resizing the current transformer for metering, etc.

Advantages
•    AC current logger
•    Used with current sensor with mA output (banana plugs)
•    Own power supply

Specifications:
•    1 channel
•    Input connections: 2 recessed banana sockets
•    Output current range: 0 to 1 A (depending on the probe)
•    Resolution: 0.1 mA
•    Sampling rate: 64 samples per period
•    Storage interval from 125 ms to 1 jour
•    Recording modes: Start/End, FIFO, XRM extended recording mode
•    Recording duration from 15 min to 8 weeks, programmable using DataView
•    Memory: 240,000 measurements (512 kB)
•    Communication: optical USB 2.0
•    Power supply: 2 x AA 1.5 V batteries
•    Battery life: 100 hours to more than 45 days

PEL105 digital current logger clamp

Chauvin Arnoux Make PEL105 Power & energy Logger

The PEL 105 logger is particularly simple to use with an all-terrain IP67 casing capable of withstanding shocks, UV rays and extreme temperatures. It is ideal for outdoor installation directly on an electricity pole. With its 1,000 V CAT IV safety rating, it can be used for measurements on all LV networks, including measurements of the neutral-earth voltage and the neutral current. This stand-alone instrument is equipped with a self-powering system via its voltage inputs up to 1,000 V. The PEL 105 offers 5 voltage inputs and 4 current inputs. Compatible with a large number of current sensors to make it easier to use, it also recognizes the sensors automatically. The PEL 105 can be used to measure, record and analyse the power values (W, var, VA) and energy values (kWh, kvarh, kVAh). At the same time, they record the PF and the DPF. Recording is continuous with a sampling interval of 200 ms.

Advantages
•    5 voltage inputs & 4 current inputs
•    All-terrain shockproof casing resistant to UV light and high temperatures
•    Ideal for mounting on electricity poles
•    Self-powered by its voltage inputs up to 1,000 V
•    Continuous recording at 200 ms intervals
•    Measurements in compliance with IEEE 1459

L702 digital current logger clamp

Chauvin Arnoux Make L702 logger

The Simple Logger II L702 monitors and records temperature and relative humidity. This logger is ideal for applications in clean rooms, wine cellars, paper mills, greenhouses, etc.

Advantages
•    Thermo-hygrometer
•    Own power supply

Specifications:
•    From -10 °C to +50 °C (14 °F to 122 °F) and from 5 to 85% RH
•    Choice of 4 storage modes
•    Up to 240,000 measurements stored in non-voltaile measurements
•    Powered by standard alkaline batteries giving a battery life of 45 days or more
•    Lightweight and compact for use in all situations
•    5 LED indicators for quick, clear display of the logger's status
•    IEC 61010 50 V CAT III

L481 digital current logger clamp

Chauvin Arnoux Make L481 logger

The Simple Logger II models automatically adapt their sensitivity (measurement range) and their acquisition rate to optimize recording. It is possible to program alarms or triggers on thresholds or on a predefined range. The LEDs on the front panel enable users to check the status of the logger and the remaining storage capacity at a glance. Compact and battery-powered, the Simple Logger II L481 is easy to position, even in an electrical cabinet.

Advantages
•    DC voltage logger
•    Detection of intermittent voltage faults
•    Own power supply

Specifications:
•    Bipolar voltage logging up to ±850 Vdc
•    Programmable storage rate from 8 per second to 1 per day
•    3 storage modes as required
•    Storage of up to 240,000 measurements in non-volatile memory
•    Powered by standard alkaline batteries
•    Lightweight and compact, fit anywhere
•    5 LED indicators for checking the instrument's status at a glance
•    DataView® software supplied FREE with instrument for data storage, real-time waveform display, analysis and report generation
•    Delivered with an isolated USB communication cable and batteries
•    IEC 61010-1  300 V CAT IV and 600 V CAT III

L261 digital current logger clamp

Chauvin Arnoux Make L261 LOGGER

The L261 logger is ideal for industrial, commercial or residential supervision, monitoring of voltage harmonics, long-term power supply monitoring, etc.

Advantages
•    Industrial and residential monitoring
•    AC/DC RMS voltage logger
•   Own power supply

Specifications:
•    1 input channel
•    Input connection: 2 recessed banana sockets
•    Range: 0 to 600 VAC/DC
•    Resolution: 0.1 V
•    Sampling rate: 64 samples per period
•    Storage interval: programmable from 125 ms to 1 day
•    Recording modes: Start/End, FIFO, XRM extended recording mode
•    Recording duration: 15 min to 8 weeks, programmable with DataView
•    Memory: 240,000 measurements (512 kB)
•    Communication: optical USB 2.0
•    Power supply: 2 x AA 1.5 V batteries
•    Battery life: 100 hours to more than 45 days
•    Electrical safety: IEC 61010 300V CAT IV and 600V CAT III

L101 digital current logger clamp

Chauvin Arnoux Make L101 logger

The Simple Logger II family of data loggers is a product line benefiting from advanced design and an excellent quality/price ratio when their specifications and functions are taken into account. The Simple Logger II L101 is ideal for the following applications: representation of the load, detection of fault currents or intermittent problems, monitoring of the neutral current and harmonic currents with DataView.

Advantages
•    AC current logger
•    Used with current sensor with mV output (BNC)
•    Own power supply

Specifications:
•    1 BNC channel
•    Output voltage range of the current sensor: 0 to 1 V
•    Resolution: 0.1 mV
•    Sampling rate: 64 samples/period
•    Storage interval: programmable from 125 ms to 1 day
•    Recording modes: Start/End, FIFO, XRM extended mode, on Alarm
•    Recording duration: 15 minutes to 8 weeks, programmable with DataView
•    Memory: 240,000 measurements (512 kB)
•    Communication: optically-isolated USB 2.0
•    Power supply/battery life: 2 x AA 1.5 V batteries / 100 hrs to more than 45 days

ML912 digital current logger clamp

Chauvin Arnoux Make ML912 logger

For network monitoring, the ML912 logger acquires 64 samples per period. Frequency monitoring is performed on a range of ±2 Hz around the network's rated frequency (50 ou 60 Hz). The harmonic measurements are calculated from these 64 samples (available in the DataView® software). This Simple Logger® II model stores the TRMS values up to 8 times per second depending on the storage interval programmed by the user. The TRMS calculations are performed on a single period.

Advantages
•    2-channel current logger
•    Own power supply

Specifications
•    1 to 1,000 AAC
•    2 ranges: 100 and 1,000 AAC
•    152mm sensors
•    Battery-powered
•    USB link
•    Compatible with DataView®
•    Number of measurements: 240,000
•    Sampling rate: 64 per period
•    Recording rate from 8 measurements/s to 1 measurement/day

L322 digital current logger clamp

Chauvin Arnoux Make L322 logger

The L322 logger is ideal for monitoring Process current loops over long periods.
Equipped with 512 kB of internal memory management simply by selecting the appropriate recording mode and sampling rate. The XRM extended recorded mode is intagrated in the functions of each model. These comprehensive loggers also offer tools for programming alarms, as well as triggers with delays, on thresholds or according to a given range.

LEDs on the front panel enable users to check the logger's status and the storage capacity used at a glance.

Advantages
•    4-20mA current loops
•    Own power supply

Specifications:
•    2 independent input channels
•    -20 to +20 mAdc
•    Storage interval programmable from 8 per second to 1 per day
•    Choice of 3 recording modes
•    Storage of up to 240,000 measurements in non-volatile memory
•    Scaling and choice of measurement unitsz via software before saving
•    Powered by standard alkaline batteries
•    Lightweight and compact, suitable for situations where access is difficult
•    5 LED indicators for checking the instrument's status at a glance
•    DataView® software supplied FREE with instrument for data storage, real-time waveform display, analysis and report generation
•    Delivered with USB cable

L102 digital current logger clamp

Chauvin Arnoux Make L102 logger

Description
The Simple Logger II family of data loggers is a product line benefiting from advanced design and an excellent quality/price ratio when their specifications and functions are taken into account. The Simple Logger II L102 is ideal for the following applications: monitoring of split-phase loads and neutral/earth current, detection of intermittent problems, monitoring of harmonic currents with DATAVIEW, monitoring of machine loads, etc.

Advantages
•    AC current logger
Used with current sensor with mV output(BNC)
Own power supply

Specifications:
•    2 BNC channels
•    Output voltage range of current probe: 0 to 1 V
•    Resolution: 0.1 mV
•    Sampling rate: 64 samples/period
•    Storage interval: programmable from 125 ms to 1 day
•    Recording modes: Start/End, FIFO, XRM extended recording mode, on alarm
•    Recording duration: 15 minutes to 8 weeks, programmable with DataView
•    Memory: 240,000 measurements (512 kB)
•    Communication: optically-isolated USB 2.0
•    Power supply/battery life: 2 x AA 1.5 V batteries / 100 hrs to more than 45 days

AL834 digital current logger clamp

Chauvin Arnoux Make AL834 logger

Ready to use (no prior configuration required), the Simple Logger II models automatically adapt their sensitivity (measurement range) and acquisition rate to optimize the recordings. It is possible to program alarms or triggers on thresholds or on a predefined range. LEDs on the front panel allow users to check the logger's status and the storage capacity used at a glance. Compact and battery-powered, they are easy to position even in an electrical cabinet.

Advantages
•    4-channel current logger
•    IP65 ingress protection
•    Own power supply

L452 digital current logger clamp

Chauvin Arnoux Make L452 Logger

Ideal for your industrial process applications, such as measurement, dosing or environmental monitoring, the L452 is equipped with 2 inputs. It allows you to connect various types of sensors to the input in order to record varied data:
•    4-20 mA modules
•    0-10 V modules

These modules can also be used to record various data such as:
•    Temperature
•    Humidity
•    Air speed

For each of the channels, a real-time measurement is displayed on the LCD screen. The L452 communicates via a USB input and the Bluetooth function for configuration and data transfer onto a PC.

Its ergonomics makes it even simpler to use: magnetized rear panel, Multifix system, desktop stand. It operates on rechargeable batteries or the mains supply.

Advantages
•    Current and voltage logger (4-20 mA & 0-10 V)
•    Event counter
•    Dry contact closure
•    Logical level detection

ML914 digital current logger clamp

ML914 LOGGER

The Simple Logger II ML914 offers ranges up to 100 A and 1,000 A. Four MiniFLEX-type flexible current sensors are used for these measurements.

The data storage modes and measurement acquisition interval are user-programmable using the DataView® application software delivered with the product. Up to 1,000,000 measurements can be stored in the Simple Logger® II ML914's non-volatile internal memory.

Advantages
•   4-channel current logger
•   Own power supply
•   MiniFlex current sensors

Specifications
•    1 AAC to 1,000 AAC
•    2 current ranges: 100 and 1,000 A
•    Recording duration from 15 min to 8 weeks (depending on the recording interval)
•    1,000,000 measurements
•    IEC 61010 600V CAT IV and 1000V CAT III

no-image

L642 LOGGER

The Simple Logger® II L642 is a 2-channel temperature logger for thermocouples.

The Simple Logger II range of data loggers from Chauvin Arnoux offers an excellent quality/price ratio when their specifications and functions are taken into account. Selection of the data storage mode and sampling rate enables users to configure these loggers very simply in order to optimize memory management according to the application in progress. These loggers offer a broad palette of useful functions for your applications, including the XRM™ extended recording mode and triggering with a delay.

Advantages
•    Monitoring of temperature variations
•    Own power supply

Specifications:
•    2 inputs with thermocouple-type mini-connectors
•    -250 °C to +1767 °C
•    240,000 measurements
•    Recording capacity of up to 8 weeks
•    USB port
•    IEC 61010 50V CAT III

Get Quote

About Us

At CIPL, we express who we are, through our Guiding Principles, Mission, Core Values and Objectives. Developed over time, each represent philosophy or goal that is intrinsically important to the organization. We invite you to explore these four ways of understanding CIPL as an organisation.

Contact Us

Cyronics Instruments Pvt Ltd.

CORPORATE OFFICE :
#11, Electronic Co-operative Estate,
Pune – Satara Road,
Pune 411009.
Maharashtra, INDIA
Boardline    :   +91 20-24208200
Faxline       :   +91 20-24208202

icon facebookicon twittericon linkedinicon googleplus