Chauvin Arnoux Make F62 Leakage Current Multimeter Clamp
In the event of an insulation fault or untimely tripping of RCDs, the F62 clamp is the ideal tool for detecting and measuring the leakage currents flowing to earth.
The versatile F62 clamp also offers all the functions of a multimeter clamp.
Specifications:
• 10,000-count backlit display
• Current: 30 µA to 100 A AC
• Resolution : 10 µA
• 50/60 Hz anti-harmonic filter
• High immunity to eddy currents: 70 dB
• AC/DC voltage: 0.1 V to 600 V
• Frequency: 5 Hz to 1 kHz
• Resistance: 0.1 Ω to 1 kΩ
• Audible continuity: < 35 Ω
• Functions: Max, Relative, display memorization
• Automatic power-off with battery status indication
• 300 V CAT III
Chauvin Arnoux Make F65 Leakage Current Multimeter Clamp
In the event of an insulation fault or untimely tripping of RCDs, the F65 clamp is the ideal tool for detecting and measuring the leakage currents flowing to earth.
The versatile F65 clamp also offers all the functions of a multimeter clamp.
In addition, the F65 clamp is equipped with an RMS converter to ensure that the measurements remain accurate even in the presence of distorted signals.
Specifications:
• 10,000-count backlit display
• Current: 30 µA to 100 A AC
• Resolution: 10 µA
• 50/60 Hz anti-harmonic filter
• High immunity to eddy currents: 70 dB
• AC/DC voltage: 0.1 V to 600 V
• Frequency: 5 Hz to 1 kHz
• Resistance: 0.1 Ω to 1 kΩ
• Audible continuity: < 35 Ω
• Functions: Max, Relative, display memorization
• Automatic power-off with battery status indication
• 300 V CAT III
Chauvin Arnoux Make C.A 6160 Multifunction Electrical Equipment Tester
The C.A 6160 is a powerful portable instrument for complete certification testing of a broad range of electrical appliances and equipment: dielectric test, continuity, voltage drop, insulation resistance, leakage current, discharge time and functional testing.
• dielectric test: standard measurement modes (Un from 100 to 5,000V with Ilim 500mA) and programmed modes (t1, t2, t3, U1, U2)
• continuity: up to 100 Ω with 0.1 < Itest < 25 A
• voltage drop: up to 100V (Itest > 10 A)
• insulation resistance: up to 1 GΩ at 250/500 VDC and 1,000 VDC
• measurement of internal and external discharge time (at the socket)
• leakage current: operating and residual up to 20 mA, contact up to 2 mA
• functional testing: voltage, current, frequency and power
• AUTOTEST function for automatic execution of measurement sequence (up to 50)
• large memory: 1,600 measurements
• software to upload the stored data, generate test reports and program measurement sequences
• delivered with all necessary measurement cables as standard and many optional accessories
• dimensions: 410 x 175 x 370 mm - weight: 13.5 kg