Chauvin Arnoux Make C.A 861 Contact Thermometer
Protected by a shockproof sheath in a compact case, the Physics Line C.A 861 thermometer, fitted with a K-type thermocouple input, measures temperatures between -40 and +1,350°C, with a typical accuracy of ± (0.1 % of reading + 1 °C).
• One K-thermocouple input
• Measurement range: - 40 °C to + 1,350 °C
• Accuracy ± (0.1 % of reading + 1 °C)
• Functions: MAX / HOLD / °C or °F / Backlighting
• Resolution: 0.1 °C or 1 °C
• Shockproof protective sheath
• Dimensions: 173 x 60.5 x 38 mm
• Weight: 185 g
Chauvin Arnoux Make C.A 863 Contact Thermometer
Protected by a shockproof sheath in a compact case, the Physics Line C.A 863 differential thermometer is equipped with 2 inputs for K-type thermocouples and measures temperatures and temperature differences between -50 and +1,300 °C, with a typical accuracy of (0.3 % of reading + 1 °C).
• Two K-thermocouple inputs
• ΔT differential temperature measurements
• Measurement range: - 50 °C to + 1,300 °C
• Accuracy ± (0.3 % of reading + 1 °C)
• Functions: MAX / HOLD / °C or °F / Backlighting
• Resolution: 0.1 °C or 1 °C
• Shockproof protective sheath
• Dimensions: 173 x 60.5 x 38 mm
• Weight: 185 g
Chauvin Arnoux Make C.A 865 Contact Thermometer
Protected by a shockproof sheath in a compact case and equipped with a Pt 100Ω sensor input, the Physics Line C.A 865 thermometer measures temperatures between -50 and +200°C.
• 1 input with Pt 100 sensor
• Measurement range: - 50 °C to + 200 °C
• Accuracy: ± 0.5 °C
• Resolution: 0.1 °C
• Functions: MAX / HOLD / °C or °F / Backlighting
• Shockproof protective sheath
• Dimensions: 173 x 60.5 x 38 mm
• Weight: 175 g
Chauvin Arnoux Make TK 2000 Contact Thermometer
IP65 thermometer with 1 K-thermocouple input equipped with a HOLD function.
• Measurement range: -50 °C to 1,000 °C
• Accuracy: ±1 °C from -50 °C to 0 °C and ±1.5% ± 0.5 °C from 0 to 1,000 °C
• Resolution: 0.1 or 1 °C
• Dimensions: 63 x 163 x 37.5 mm
• Weight: 200 g
• Delivered with 1 flexible K-thermocouple sensor for measurements from –40 °C to +200 °C
Chauvin Arnoux Make TK 2002 Contact Thermometer
IP65 thermometer with 2 K-thermocouple inputs equipped with a HOLD function.
• Measurement range: -50 °C to 1,000 °C
• Accuracy: ±1 °C from -50 °C to 0 °C and ±1.5% ± 0.5 °C from 0 to 1,000 °C
• Resolution: 0.1 or 1 °C
• Dimensions: 63 x 163 x 37.5 mm
• Weight: 200 g
• Delivered with 1 flexible K-thermocouple sensor for measurements from –40 °C to +200 °C
Chauvin Arnoux Make C.A 871 Non-Contact Thermometer
The C.A 871 thermometer can be used for simple, accurate remote measurements.
• Measurement range: - 40 °C to + 538 °C
• Accuracy: ± (2.5 % of reading + 2 °C)
• Resolution: 0.1 °C between - 40 and 100 °C (1 °C otherwise)
• Laser sighting
• Fixed emissivity: 0.95
• Distance/spot ratio (D/ø): 8/1
• Backlighting
• Dimensions: 160 x 82 x 41.5 mm
• Weight: 180 g
Chauvin Arnoux Make C.A 876 Non-Contact Thermometer
In its compact, shockproof casing, the Physics Line C.A 876 Digital Thermometer is equipped with a built-in infrared probe and a K-thermocouple input.
• Range from - 20 to + 550 °C
• Adjustable emissivity from 0.1 à 1
• Distance/spot ratio (D/ø): 10/1
• Laser sighting
• Accuracy: ± 2 % of reading or 3 °C
• Resolution: 1 °C
Measurements with K thermocouple
• Range from - 40 to + 1,350 °C
• Accuracy: ± (0.1 % of reading + 1 °C)
• Resolution: 1 °C
Chauvin Arnoux Make C.A 879 Non-Contact Thermometer
This pocket no-contact thermometer provides simple and accurate remote temperature measurements. The deactivatable trigger can be locked to detect hot points by scanning.
• Resolution: 0.1 °C
• Measurement from - 50 °C to + 550 °C
• Accuracy: ± (1.5 % of reading + 2 °C)
• Laser sighting
• Fixed emissivity: 0.95
• Distance/spot ratio (D/ø): 12/1
• Hold
• Backlighting
• Dimensions: 230 x 100 x 56 mm
• Weight: 290 g
Chauvin Arnoux Make C.A 1864 Non-Contact Thermometer
This no-contact thermometer offers the possibility of adjusting the emissivity for inspections that match reality. To detect hot spots, a simple scan of the target is all it takes (scanner function). Equipped with an extensive temperature range, it also has a high distance/spot targeting ratio. Alarm thresholds can be set to warn of any temperature overruns.
• Wide measurement range: – 50 °C to + 1,000 °C
• Accuracy: ± (1.5 % of reading + 2 °C)
• Distance/spot ratio: 30/1
• High and Low alarms
• Min / Max / Average / HOLD
Chauvin Arnoux Make C.A 1866 Non-Contact Thermometer
This no-contact thermometer offers the possibility of adjusting the emissivity for inspections that match reality. To detect hot spots, a simple scan of the target is all it takes (scanner function). Equipped with an extensive temperature range, it also has a high distance/spot targeting ratio. Alarm thresholds can be set to warn of any temperature overruns.
• Wide measurement range: – 50 °C to + 1,000 °C
• Accuracy: ± (1.5 % of reading + 2 °C)
• Distance/spot ratio: 50/1
• High and Low alarms
• Min / Max / Average / HOLD