Cyronics - Industrial Division

 
Chauvin Aurnox

Analog Multimeter CA 5005

Chauvin-Arnoux make CA 5005: Analog Multimeter

The C.A 5005 is a very competitively-priced analogue multimeter designed to meet all the needs of electricians.

It is delivered with a current clamp allowing measurement (with direct readings) of AC currents up to 200 A AC.

Specifications:
•    DC voltage: 100 mV to 600 V (8 ranges)
•    AC voltage: 10 V to 600  V (5 ranges)
•    DC current: 50 µA to 10 A (6 ranges)
•    AC current: 3 A to 240 A (5 ranges) with MN89 clamp supplied
•    Automatic calibration
•    “Voltest” LED if voltage present in ohmmeter mode
•    Typical accuracy: 1.5%
•    Impedance: 20 kΩ/V
•    Resistance: 10 kΩ and 1 MΩ
•    Audible continuity test: R < 50 Ω
•    dB scale (AC voltages)
•    Fuse status LED
•    Dimensions: 160 x 105 x 56 mm
•    Weight: 500 g
•    IP53
•    Use on any installation rated lower than or equal to CAT III 600 V as per IEC/EN 61010-1 Edition 2

Analog Multimeter CA 5003

Chauvin-Arnoux make CA 5003: Analog Multimeter

The C.A 5003 is a very competitively-priced analogue multimeter designed to meet all the needs of electricians.

Specifications:
•    DC voltage: 100 mV to 600 V (8 ranges)
•    AC voltage: 10 V to 600 V (5 ranges)
•    DC current: 50 µA to 15 A (7 ranges)
•    AC current: 1.5 mA to 15 A (5 ranges)
•    Automatic calibration
•    “Voltest” LED if voltage present in ohmmeter mode
•    Typical accuracy: 1.5%
•    Impedance: 20 kΩ/V
•    Resistance: 10 kΩ and 1 MΩ
•    Audible continuity test: R < 50 Ω
•    dB scale (AC voltages)
•    Fuse status LED
•    Dimensions: 160 x 105 x 56 mm
•    Weight: 500 g
•    IP53
•    Use on any installation rated lower than or equal to CAT III 600 V as per IEC/EN 61010-1 Edition 2

Analog Multimeter CA 5001

Chauvin-Arnoux make CA 5001: Analog Multimeter

The C.A 5001 is a very competitively-priced analogue multimeter designed to meet all the needs of electricians.

Specifications:
•    DC voltage: 100 mV to 600 V (8 ranges)
•    Accuracy: 1.5% except with 100 mV range (2.5%)
•    AC voltage: 10 V to 600 V (5 ranges)
Bandwidth: [20Hz-100kHz] on 10 V range,  [20Hz-1kHz] on 300 V and 1,000 V ranges
Accuracy: 2.5% except with 100 mV range (3%)
•    Impedance: 20 kΩ/V
•    DC current: 50 µA to 5 A (5 ranges)
•    AC current: 5 mA to 5 A (4 ranges)
Bandwidth: [40 Hz-5 kHz]
Accuracy: 2.5% except with 5 A range(5%)
•    Resistance: 10 kΩ and 1 MΩ
•    Audible continuity test: R < 50 Ω
•    dB scale (V AC).
•    Fuse status LED
•    Dimensions: 160 x 105 x 56 mm
•    Weight: 500 g
•    Use on any installation rated lower than or equal to CAT III 600 V as per IEC/EN 61010-1 Edition 2

Analog Multimeter MX 1

Metrix A Chauvin Arnoux Brand Make MX 1: Analog Multimeter

As rugged and sturdy as a 4x4 vehicle, the MX 1 can stand up to use on any site thanks, in particular, to its rugged, water-resistant moulded casing. It benefits from protection on all its ranges and all the ranges offer a safety alarm when the instruments is used as an ohm-meter.

The MX 1 is also available in a hard case.

Specifications:
•    DC voltage from 150 mV to 600 V
•    Class 2 basic accuracy
•    AC voltage from 5 V to 600 V
•    Average measurement
•    Bandwidth from 16 Hz to 1 kHz
•    DC current from 50 µA to 10 A
•    AC current from 500 µA to 10 A
•    Resistance from 20 kΩ  to 2 MΩ
•    Continuity with buzzer
•    Diode test
•    dB from -6 to 66
•    Dimensions: 155 x 98 x 40 mm
•    Weight: 420g
•    IP65 protection
•    Use on any installation lower than or equal to CAT III 600 V as per IEC/EN 61010-1 Edition 2

Analog Multimeter MX 2 B

Metrix A Chauvin Arnoux Brand Make MX 2: Analog Multimeter

The MX 2B stands up to use on any site thanks, in particular, to its rugged moulded casing which is also water-resistant. It benefits from protection on all its ranges and there is a safety alarm when it is used as an ohmmeter.

The current clamp delivered as standard with the multimeter can be used to measure AC currents up to 200A in total safety by avoiding having to open the main circuit.

Specifications:
•    DC voltage from 150 mV to 600 V
•    Class 2 basic accuracy
•    AC voltage from 5 V to 600 V
•    Bandwidth from 16 Hz to 1 kHz
•    DC current from 50 µA to 10 A
•    AC current up to 200 A with clamp
•    Resistance from 20 kΩ to 2 MΩ
•    Continuity with buzzer
•    Diode test
•    dB scale from -6 to 66
•    IP65 protection
•    Dimensions: 155 x 98 x 40mm
•    Weight: 420g
•    Use on any installation lower than or equal to CAT III 600 V as per IEC/EN 61010-1 Edition 2

Get Quote

About Us

At CIPL, we express who we are, through our Guiding Principles, Mission, Core Values and Objectives. Developed over time, each represent philosophy or goal that is intrinsically important to the organization. We invite you to explore these four ways of understanding CIPL as an organisation.

Contact Us

Cyronics Instruments Pvt Ltd.

CORPORATE OFFICE :
#11, Electronic Co-operative Estate,
Pune – Satara Road,
Pune 411009.
Maharashtra, INDIA
Boardline    :   +91 20-24208200
Faxline       :   +91 20-24208202

icon facebookicon twittericon linkedinicon googleplus